Buy ASTM D TEST METHOD FOR ENTHALPIES OF FUSION AND CRYSTALLIZATION OF POLYMERS BY DIFFERENTIAL. ASTM D Standard Test Method for Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC). Designation: D – AMERICAN SOCIETY FOR TESTING AND MATERIALS Barr Harbor Dr., West Conshohocken, PA Reprinted from the.

Author: Yozshunris Neshura
Country: China
Language: English (Spanish)
Genre: Automotive
Published (Last): 26 April 2005
Pages: 140
PDF File Size: 9.13 Mb
ePub File Size: 2.28 Mb
ISBN: 845-4-13620-482-2
Downloads: 16237
Price: Free* [*Free Regsitration Required]
Uploader: Tem

You may delete a document from your Alert Profile at any time. Ast 4- To date, there is no similar or equivalent approved ISO d33417. Please first log in with a verified email before subscribing to alerts. Compact solids granulates, components, molds, etc. The DSC Sirius combines compactness, robustness and ease-of-use with high detection sensitivity, thus offering optimal conditions for quality assurance and failure analysis in areas such as foods, cosmetics, polymers, technical textiles, and organic and inorganic materials.

We have no document history for this standard. Subscription pricing is determined by: We use cookies to personalize content and ads, provide social media features and analyze traffic to our website. The DSC Polyma is a completely new concept. Numerous upgrade possibilities allow adaption of this cost-effective xstm system to sophisticated applications.

By using this site you agree to the placement of cookies on your computer in accordance with the terms of our data protection policy. Add to Alert PDF. Note d34117 heats of fusion can only be determined in conjunction with structure investigation and frequently specialized crystallization techniques are needed.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

To request a quote for this test or others Click Here. This standard is also available to be included in Standards Subscriptions. The sample is heated at a controlled rate and a plot of heat flow versus temperature is produced. 3d417

  BOOK OF OCCASIONAL SERVICES PCUSA PDF

Differential Scanning Calorimetry (DSC)

Due to its versatility and the high significance of its analytical output, differential scanning calorimetry DSC is the most often employed method for thermal analysis. Characteristic temperatures melting, crystallization, polymorphous transitions, reactions, glass transition Melting, crystallization, transformation and reaction heats enthalpies Crystallinity of semi-crystalline substances Decomposition, thermal stability Oxidative stability OIT, OOT — oxidative-induction time and oxidation onset temperature, respectively Degree of curing in resins, adhesives, etc.

Combined with an FTIR analysisa DSC thermal scan can be used to help further identify certain types of materials by their melting points and is a useful tool for checking plastic parts or resins for contamination not seen by FTIR.

Play Differential Scanning Calorimeter Video. This standard does not purport to address all of the safety concerns, if any, associated with its use. All NETZSCH DSC instruments work in accordance with the heat-flux principle and feature high detection sensitivity and long service lives — ideal conditions for successful application in research and academia, material development and quality control. Due to copyright restrictions, we are not able to provide copies of standards.

The resulting thermal scan is then analyzed. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. A sample weight of 10 to 15 mg is required.

Differential Scanning Calorimetry (DSC) – Argen Polymer LLC

Using a DSC differential scanning calorimeter the following are commonly determined: It is also axtm to characterize materials for their thermal performance. As the voice adtm the U. It unites excellent performance and highest flexibility. Further application areas include determining the effect of light on the shelf life of foods or technical oils, fats and lubricants.

We have no amendments or corrections for this standard. The sample compartment is where an encapsulated sample of about 10 to 15 milligrams is placed for testing. If the document is revised or amended, you will be notified by email. Please first verify your email before subscribing to alerts. Eutectic purity Specific heat c p Compatibility between components Influence of aging Distribution of the molecular weight peak form for polymers Impact of additives, softeners or admixtures of re-granulates for polymer materials What is the Difference Between DSC and DTA?

  CATALOGUE COP COPINE HIVER 2012 PDF

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Note 2-This test method may not be applicable to all types of polymers as written see 6. We use cookies to personalize content and ads, provide social media features and analyze traffic to our website.

Please upgrade your browser

This standard is not included in any packages. Already Subscribed to this document. The DSC head area contains equivalent sample and reference compartments located adjacent to each other. This test method covers the determination of heat of fusion and heat of crystallization of polymers by differential scanning calorimetry. By using this site you agree to the placement of cookies on your computer in accordance with the terms of our data protection policy.

Sensors with high calorimetric sensitivity, short time constants and a condensation-free sample chamber in the calorimeter cell guarantee high atsm sensitivity and stable, reproducible baselines over the entire life cycle of a calorimeter: Your Alert Profile lists the documents that will be monitored.

Designed especially for the characterization of polymer materials, its integral approach astk not only of the DSC instrument alone, but also incorporates the entire analytical process chain from sample preparation to evaluation.

Proceed to Checkout Continue Shopping. The reference compartment contains an empty aluminum pan and cover equivalent to those used to encapsulate a test sample. Standards can be obtained from appropriate standards authorities.

Of course, our Differential Scanning Calorimeters DSC meet the respective instrument and application standards, including: